2-Zone Conventional Fire Alarm Panel for Home Security

Still deciding? Get samples of $ !
Order Sample
Product Details
Customization: Available
Type: Fire Alarm Host
Function: Networked, Non-Networked
Shipping
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Guarantee
Payment Methods:
  • visa
  • mastercard
  • discover
  • JCB
  • diners club
  • american express
  • T/T
  • PIX
  • SPEI
  • OXXO
  • PSE
  • OZOW
  • PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (10)
2-Zone Conventional Fire Alarm Panel for Home Security pictures & photos
2-Zone Conventional Fire Alarm Panel for Home Security pictures & photos
2-Zone Conventional Fire Alarm Panel for Home Security pictures & photos
2-Zone Conventional Fire Alarm Panel for Home Security pictures & photos
2-Zone Conventional Fire Alarm Panel for Home Security pictures & photos
  • 2-Zone Conventional Fire Alarm Panel for Home Security
  • 2-Zone Conventional Fire Alarm Panel for Home Security
  • 2-Zone Conventional Fire Alarm Panel for Home Security
  • 2-Zone Conventional Fire Alarm Panel for Home Security
  • 2-Zone Conventional Fire Alarm Panel for Home Security

Find Similar Products

Overview

Basic Info.

Model NO.
XHA1002
Usage
Door, Personal, Window, Fire, Smoke
Certification
CE
Alarm Volume (within 1m)
≥80dB
Back up Battery
1*12V Sealed Lead Acid
Power Supply
90-270VAC
Connected
Wired Conventional 2 Zone Smoke Alarm Panel
Installation
Wall Mounted
Application
Smoke Alarm System
Transport Package
Carton
Specification
370mm*440mm*100mm
Trademark
XHA
Origin
China
HS Code
8531100000
Production Capacity
5000pieces/Year

Packaging & Delivery

Package Size
50.00cm * 27.00cm * 34.00cm
Package Gross Weight
290.000kg

Product Description

Product Description


Conventional 2 Zone Fire Alarm Panel For Fire Safety Alarm System

2-Zone Conventional Fire Alarm Panel for Home Security

 

 



Introduction

 

The information provided in this guide pertains to the Master and Slave fire alarm control panels. The panel series is engineered to comply with the standards outlined in EN54 Parts 2 & 4.

These fire alarm control panels (2 Zones) incorporate all the advanced features expected from a state-of-the-art conventional fire alarm system, while also offering ease of use and efficient installation methods preferred by both installers and building occupants.

A wide range of supplementary devices is available to integrate with the fire control panels, including optical, ionization, photoelectric, photoelectric-thermal, and heat detectors.

Each component of the system has been specifically designed to function seamlessly as part of the overall setup. This ensures full compatibility between the control panel, smoke detectors, interface devices, and other auxiliary components, with all system functionalities fully supported by each individual device.




Product Features

 
2 conventional input zones.
Each zone can be connected with 30 conventional fire detectors. Each panel has external devices control output points, Through the points, the panel can control such external devices as bell, siren, flame detector, beam detector etc.
Dedicated alarm and trouble relays.
1 RS485 can be able to connect the other panel.
Housed in a 370mm W x 440mm H x 100mm D metal enclosure.
Enclosure supports 1 12V, 2.3Ah backup batteries.
The panel can be used independently or connect by RS485.
 
 

Specification

 

 

Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.90 Amps @ 26VDC
Initiating Device Circuits Zones Alarm Zone 2/4/8/16
Normal Initiating Operating Voltage 22VDC, Maximum 26VDC, regulated
Normal Monitor Current <50mA
Alarm Current <150 mA
Short Circuit Initiating Current (per zone) 35mA Maximum
Maximum Initiating Resistance (per zone) 10 ohms
Initiating End-of-Line Resistor 4K7 ohms, 1/2W 5%
Standby Detector Current (per zone) 4mA maximum
Maximum Detector Count (per zone) 30 detectors
Initiating Cabling Type 18AWG Twisted Shielded pair (14 - 18 AWG)
Detector Base Impedance 430 ohms
Fault Relay rating 2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating 2A & 30VAC, resistive

 


Connection Diagram

2-Zone Conventional Fire Alarm Panel for Home Security

 



Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

Conpany Profile
2-Zone Conventional Fire Alarm Panel for Home Security2-Zone Conventional Fire Alarm Panel for Home Security


Assembly Line
2-Zone Conventional Fire Alarm Panel for Home Security

Burn-in Room
2-Zone Conventional Fire Alarm Panel for Home Security

Quality Management System
2-Zone Conventional Fire Alarm Panel for Home Security

Send your message to this supplier

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now