Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems

  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Photoelectric Detection Technology: Uses state-of-the-art optical sensing chamber for reliable smoke detection.
  • Wide Operating Voltage Range: Operates efficiently within 9 to 28VDC for versatile system integration.
  • OEM and ODM Services: Custom manufacturing solutions available for specific client requirements.
  • Comprehensive Warranty: Includes a 1-year warranty covering mechanical defects and parts.
  • Fast Lead Time: Standard delivery within 15 working days for both peak and off-peak seasons.
  • CE and EN54 Certification: Meets international safety standards with CE and EN54 certifications.

Product Images of Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems

Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems pictures & photos
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems pictures & photos
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems pictures & photos
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems pictures & photos
Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
  • Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
  • Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
    Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
  • Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
    Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
  • Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
    Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
  • Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
    Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems

Find Similar Products

Product Description

Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems

Introduction


XHA102 Conventional photoelectric smoke detector adopts non-polar signal two-bus communication mode, which can be used for smoke detection in conventional fire alarm system, the control box of fire shutter door/fire rolling shutters, and can also be connected to the circuit of various fire alarm controllers produced by other company to realize smoke detection and early alarm monitoring functions.


Specifications


Operating Voltage Range:        9 to 28VDC Volts Non-polarized
Standby Current:                ≤60µA @ 24 VDC
Maximum Alarm Current (LED on: ) ≤30mA @ 24 VDC
Operating Humidity Range:        10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range:    14°F to 122°F (-10°C to50°C)
Adjustable Sensitivity:             1.06±.26%FT.
Height:                        2.2˝ (55 mm) installed in Base
Diameter:                        4.0˝ (103 mm)

Weight:                        5.5 oz. (155 g)




Wiring


Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems
Warning:
Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.


Installation


BEFORE INSTALLING

NOTICE: This manual should be left with the owner/user of this equipment.
IMPORTANT: The detector must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year.
GENERAL DESCRIPTION
The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installing detectors.

1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.




Product Range


Smart Home Standalone smoke detectors and combustible/CO gas detector
4 wire smoke detectors with relay output.
2 wire smoke and heat detectors for switch fire sensor
Explosion-proof product for fire alarm system
Conventional Fire Alarm System
Addressable fire alarm system
Extinguishing control system
Wireless alarm system
Electrical fire monitor system
Fire door monitor system
Fire extinguishing Water cannon System
Industry 4 in 1 Gas detector/ Single gas detector(CO/CO2 etc)



Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



Factory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection SystemsFactory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection SystemsFactory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection SystemsFactory Price Conventional Smoke Alarm for Fire Alarm System Fire Detection Systems

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR232771". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.

About Our Factory & Business Background

Address
Tianxin Garden Phase 3, Fuyong Town, Baoan District, Shenzhen City, Guangdong Province, China
Terms of Payment
LC, T/T, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
shenzhen

Our Production Capability & Technical Expertise

Main Products
Fire Alarm Control System, Relay Output Smoke Detector, Gas Detector, Stand Alone Smoke Detector, Electrical Fire Alarm System, Fire Door Control System, Gas Fire Extinguishing Control System, Wireless Fire Alarm System, Household Security System, Fire Alarm Control Panel

Our Industry Experience & Global Business Record

Export Year
2019-09-05
Main Markets
Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe

FAQ

What is the operating voltage range?
The detector operates within a voltage range of 9 to 28VDC.
Does this smoke detector support customization?
Yes, we offer OEM and ODM services to customize the product according to your needs.
What is the warranty period for this device?
We provide a 1-year warranty for this smoke detector.
How long does it take to deliver the product?
The normal lead time is within 15 working days.
What certifications does this smoke alarm have?
The product is certified with CE and EN54 standards.
Can I order a sample before placing a bulk order?
Yes, we welcome sample orders for testing and evaluation.
What is the detection principle of this smoke detector?
It uses a photoelectric detection method with an advanced optical sensing chamber.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now