Customization: | Available |
---|---|
Type: | Smoke Detector |
Signal Transmission: | Wired Alarm |
Still deciding? Get samples of US$ 8/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introduction
The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.compatible with all brand conventional fire alarm system.
Parameters
Product Name | Smoke Detector | Rated operational voltage | 9 to 28VDC Volts Non-polarized |
Adjustable Sensitivity | 1.06±.26%FT | Static current | ≤60µA @ 24 VDC |
Alarm current | ≤30mA @ 24 VDC | Work temperature | -10°C~+50°C |
Certification | CE | Humidity | ≤95%. |
Size | 103*103*55mm | Weight | 105 g |
Feature
Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.
SMD circuit board design-satisfactory quality and reliability guaranteed
They work perfectly with all conventional intelligent fire control panels
Key Specifications/Special Features
Advanced MCU Expert Algorithm Software.
Durable sensor head, no need for replacement
Easy installation and maintenance
Installation
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.
Remove power from initiating-device circuits before installingdetectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.
Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.
Product range
Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector
Service
1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.
5. Welcome sample order.
Conpany Profile
Assembly Line
Burn-in Room
Quality Management System