En54 2 Wire Smoke Alarm

Product Details
Customization: Available
Type: Smoke Alarm
Signal Transmission: Wired Alarm
Still deciding? Get samples of US$ 8/Piece
Request Sample
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • En54 2 Wire Smoke Alarm
  • En54 2 Wire Smoke Alarm
  • En54 2 Wire Smoke Alarm
Find Similar Products

Basic Info.

Model NO.
YT102
Working Mode
/
Certification
En54
Working Principle
/
Transmission Mode
/
Alarm Volume (within 1m)
≥80dB
Receive Frequency
/
Product
Conventional Smoke Alarm
Wired
2 Wire
Sound Level
90dB
Apaitplicon
Fire Secuirty System
Adjustable Sensitivity
1.06±.26%FT
Certificaiton
En54
Transport Package
Carton
Specification
D103mm, H55mm
Trademark
XHA
Origin
China
HS Code
8531100000
Production Capacity
50000pieces/Year

Product Description

EN54 2 Wire Smoke Alarm For Conventional Fire Alarm System

 

En54 2 Wire Smoke Alarm



Introduction

The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.



Parameters

Product Name  Smoke Alarm Rated operational voltage 9 to 28VDC Volts Non-polarized
Adjustable Sensitivity 1.06±.26%FT Static current 40µA @ 24 VDC
Alarm current 30mA @ 24 VDC Work temperature -10°C~+50°C
Certification EN54 Humidity ≤95%.
Size  103*103*55mm Weight 155g

 

 

Feature

 

Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.
Key Specifications/Special Features
They work perfectly with all conventional intelligent fire control panels
Dual LEDs for 360-degree visibility
Advanced MCU Expert Algorithm Software.
Easy installation and maintenance
Durable sensor head, no need for replacement
SMD circuit board design-satisfactory quality and reliability guaranteed

 

 

Installation

 

IMPORTANT: The detector must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year.
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installingdetectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

      Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.

      En54 2 Wire Smoke Alarm

 

 


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

 

 



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.


Conpany Profile
En54 2 Wire Smoke AlarmEn54 2 Wire Smoke Alarm



Assembly Line
En54 2 Wire Smoke Alarm

Burn-in Room
En54 2 Wire Smoke Alarm

Quality Management System
En54 2 Wire Smoke Alarm

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier