En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System

  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • EN54 Certified Safety: Complies with EN54 standards for reliable fire detection performance.
  • High Visibility Indication: Dual LEDs provide 360-degree visible alarm and status indication.
  • Advanced Sensing Technology: Uses photoelectronic chamber and MCU expert algorithm for accurate detection.
  • Wide Voltage Compatibility: Operates on 9-28VDC non-polarized power supply for flexible installation.
  • Durable Sensor Design: SMD circuit board and durable sensor head ensure long-term reliability.
  • OEM/ODM Customization: Supports customized product solutions for specific client requirements.
  • Fast Lead Time: Standard production lead time is within 15 working days.
  • 1-Year Warranty: Comprehensive 1-year warranty coverage for peace of mind.

Product Images of En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System

En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System pictures & photos
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System pictures & photos
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System pictures & photos
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System pictures & photos
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System pictures & photos
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System pictures & photos
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
  • En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
  • En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
    En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
  • En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
    En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
  • En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
    En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
  • En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
    En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
  • En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
    En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
  • En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System
    En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System

Find Similar Products

Product Description

EN54 2 Wire Smoke Alarm For Conventional Fire Alarm System

Product Description

 

En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System



Introduction

The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.
Two LEDs on each detector provide local 360° visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit. The alarm can be reset only by a momentary power interruption.



Parameters

Product Name  Smoke Alarm Rated operational voltage 9 to 28VDC Volts Non-polarized
Adjustable Sensitivity 1.06±.26%FT Static current ≤40µA @ 24 VDC
Alarm current ≤30mA @ 24 VDC Work temperature -10°C~+50°C
Certification EN54 Humidity ≤95%.
Size  103*103*55mm Weight 155g

 

 

Feature

 

Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.
Key Specifications/Special Features
They work perfectly with all conventional intelligent fire control panels
Dual LEDs for 360-degree visibility
Advanced MCU Expert Algorithm Software.
Easy installation and maintenance
Durable sensor head, no need for replacement
SMD circuit board design-satisfactory quality and reliability guaranteed

 

 

Installation

 

IMPORTANT: The detector must be tested and maintained regularly following NFPA 72 requirements. The detector should be cleaned at least once a year.
INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installingdetectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

      Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.

      En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System

 

 


Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

 

 



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.


Conpany Profile
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm SystemEn54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System



Assembly Line
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System

Burn-in Room
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System

Quality Management System
En54 Conventional 2 Wired Smoke Detector for Fire Fighting Alarm System

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR232771". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.

About Our Factory & Business Background

Address
Tianxin Garden Phase 3, Fuyong Town, Baoan District, Shenzhen City, Guangdong Province, China
Terms of Payment
LC, T/T, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
shenzhen

Our Production Capability & Technical Expertise

Main Products
Fire Alarm Control System, Relay Output Smoke Detector, Gas Detector, Stand Alone Smoke Detector, Electrical Fire Alarm System, Fire Door Control System, Gas Fire Extinguishing Control System, Wireless Fire Alarm System, Household Security System, Fire Alarm Control Panel

Our Industry Experience & Global Business Record

Export Year
2019-09-05
Main Markets
Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe

FAQ

What is the operating voltage range?
The rated operational voltage is 9 to 28VDC, and it is non-polarized.
Does this detector have EN54 certification?
Yes, the device is certified under EN54 standards for fire alarm systems.
How is the alarm indication provided?
Two LEDs on each detector provide local 360-degree visible alarm indication.
What is the warranty period?
We provide a 1-year warranty for this smoke detector.
Can I order samples before bulk purchase?
Yes, sample orders are welcome for quality verification.
What is the typical lead time for production?
The normal lead time is within 15 working days.
Is OEM or ODM service available?
Yes, we offer both OEM and ODM services for customized needs.
What payment methods are accepted?
We accept LC, T/T, PayPal, Western Union, and Money Gram.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now