Fire Alarm System No/Nc Option Relay Output UV Flame Sensor

  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • UV Flame Detection: Detects UV rays from burning substances for fast response in high hazard areas.
  • High False Alarm Immunity: Insensitive to sunlight, dust, oil, fume, and humidity due to UV photosensitive tube.
  • Wide Detection Angle: 120-degree detection angle with sensitivity up to 25 meters for standard flames.
  • Relay Output Options: Relay contact load 1A@DC24V with configurable NO/NC via PCB jumpers.
  • Durable Construction: Corrosion proof, moisture resistant, and dust resistant with IP 21 rating.
  • OEM & ODM Service: Customization services available for specific product requirements.
  • Fast Lead Time: Standard 15 working days lead time for both peak and off-peak seasons.

Product Images of Fire Alarm System No/Nc Option Relay Output UV Flame Sensor

Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor pictures & photos
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor pictures & photos
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor pictures & photos
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor pictures & photos
Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
  • Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
  • Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
    Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
  • Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
    Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
  • Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
    Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
  • Fire Alarm System No/Nc Option Relay Output UV Flame Sensor
    Fire Alarm System No/Nc Option Relay Output UV Flame Sensor

Find Similar Products

Product Description

Fire Alarm System No/Nc Option Relay Output UV Flame Sensor


Introduction
 
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the
detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard
applications such as petrochemical plants, munitions factories and other areas where flammable or explosive
liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm


Specification
 
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: ≤10 mA @ 24 VDC
Alarm Current ≤30 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Protection rating: IP 21
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
Height: 45 mm installed in Base
Diameter: 103 mm
Weight: 153g

 Fire Alarm System No/Nc Option Relay Output UV Flame Sensor

Installation
 
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. Mounting Indoor Wall or Ceiling Products.
1. Attach mounting base to ceiling or wall.
2. Connect field wiring to terminals:
Terminal 1: Relay Output -COM (ZONE+)
Terminal 2: Relay Output - NO/NC (ZONE-)
Terminal 3: DC Power -
Terminal 4: DC Power +
3. To attach product to mounting base.
4. Secure product by tightening the two mounting screws in the front of the product housing.
5. The detector can be connected with Security alarm panel as Figure3. Relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by Jump JP1 on the PCB board.
6. The detector can be connected with conventional alarm panel as Figure 4. One 4.7K ohm resistor should be connected as End of Line (EOL) resistor at the last detector.
7. After the installation, power on the detector, use lighter or candle to test the detector within 3 meters.

WARNIING:
Not to install flame detector near the below subjects:
1. Halogen lamp, Electric discharge lamp, ultraviolet ray lamp.
2. Welding spark, Electric spark
3. Heavy current magnetic field, thunder discharge.
4. Direct sunlight.
5.Ultra violet radiation subjects
The UV flame detector can not detect the following:
1. The flame behind the glass or transparent resin.
2. Lighted cigarette.
3. Burning charcoal and coal cakes.
4. Burning material without flame.

Application in Conventional Fire Alarm system

Fire Alarm System No/Nc Option Relay Output UV Flame SensorFire Alarm System No/Nc Option Relay Output UV Flame Sensor

Product Range


Smart Home Standalone smoke detectors and combustible/CO gas detector
4 wire smoke detectors with relay output.
2 wire smoke and heat detectors
Explosion-proof product for fire alarm system
Conventional Fire Alarm System
Addressable fire alarm system
Extinguishing control system
Wireless alarm system
Electrical fire monitor system
Fire door monitor system
Fire extinguishing Water cannon System
Industry 4 in 1 Gas detector/ Single gas detector(CO/CO2 etc)



Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

Fire Alarm System No/Nc Option Relay Output UV Flame SensorFire Alarm System No/Nc Option Relay Output UV Flame SensorFire Alarm System No/Nc Option Relay Output UV Flame SensorFire Alarm System No/Nc Option Relay Output UV Flame Sensor

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR232771". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.

About Our Factory & Business Background

Address
Tianxin Garden Phase 3, Fuyong Town, Baoan District, Shenzhen City, Guangdong Province, China
Terms of Payment
LC, T/T, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
shenzhen

Our Production Capability & Technical Expertise

Main Products
Fire Alarm Control System, Relay Output Smoke Detector, Gas Detector, Stand Alone Smoke Detector, Electrical Fire Alarm System, Fire Door Control System, Gas Fire Extinguishing Control System, Wireless Fire Alarm System, Household Security System, Fire Alarm Control Panel

Our Industry Experience & Global Business Record

Export Year
2019-09-05
Main Markets
Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe

FAQ

What is the detection range of the UV flame detector?
The detector is calibrated to detect flames at a distance of 25 meters.
Can the relay output be changed from NC to NO?
Yes, the relay output signal can be changed from Normal Close (NC) to Normal Open (NO) by adjusting Jump JP1 on the PCB board.
What is the warranty period for this product?
We provide a 1-year warranty for this UV flame detector.
What are the operating voltage requirements?
The device operates within a voltage range of 12 to 28 VDC Volts.
Where should the detector not be installed?
Do not install near halogen lamps, electric discharge lamps, welding sparks, heavy current magnetic fields, direct sunlight, or UV radiation sources.
What is the lead time for orders?
The normal lead time is 15 working days, applicable for both peak and off-peak seasons.
Is sample ordering supported?
Yes, sample orders are welcome for this product.
What types of flames can the detector not detect?
It cannot detect flames behind glass, lighted cigarettes, burning charcoal, coal cakes, or materials without a flame.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now