Conventional 2 Zone Fire Alarm Panel

Product Details
Customization: Available
Type: Fire Alarm Host
Function: Networked, Non-Networked
Still deciding? Get samples of US$ 145/Piece
Request Sample
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • Conventional 2 Zone Fire Alarm Panel
  • Conventional 2 Zone Fire Alarm Panel
  • Conventional 2 Zone Fire Alarm Panel
  • Conventional 2 Zone Fire Alarm Panel
Find Similar Products

Basic Info.

Model NO.
XHA1002
Power Supply
90-270VAC
Connected
Wired Conventional 2 Zone Smoke Alarm Panel
Transport Package
Carton
Specification
370mm*440mm*100mm
Trademark
XHA
Origin
China
HS Code
8531100000
Production Capacity
5000pieces/Year

Product Description

Conventional 2 Zone Fire Alarm Panel For Fire Safety Alarm System

Conventional 2 Zone Fire Alarm Panel

 

 



Introduction

 

The information provided in this manual covers the Master and Slave fire alarm control panel. The panel range is designed to
meet the requirements of EN54 Parts 2 & 4.
The fire alarm control panels (2 Zones) provide all of the sophisticated features required of a leading edge conventional fire
alarm system along with the simple operation and efficient installation methods demanded by both installers and building
users.
A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization,
photoelectric, photoelectric-thermal and heat detectors.
Each of the system components has been specifically designed to operate as part of the system. This provides assurance
that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one
another and that the full range of system functionality is supported by each device.



Product Features

 
2 conventional input zones.
Each zone can be connected with 30 conventional fire detectors. Each panel has external devices control output points, Through the points, the panel can control such external devices as bell, siren, flame detector, beam detector etc.
Dedicated alarm and trouble relays.
1 RS485 can be able to connect the other panel.
Housed in a 370mm W x 440mm H x 100mm D metal enclosure.
Enclosure supports 1 12V, 2.3Ah backup batteries.
The panel can be used independently or connect by RS485.
 
 

Specification

 

 

Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.90 Amps @ 26VDC
Initiating Device Circuits Zones Alarm Zone 2/4/8/16
Normal Initiating Operating Voltage 22VDC, Maximum 26VDC, regulated
Normal Monitor Current <50mA
Alarm Current <150 mA
Short Circuit Initiating Current (per zone) 35mA Maximum
Maximum Initiating Resistance (per zone) 10 ohms
Initiating End-of-Line Resistor 4K7 ohms, 1/2W 5%
Standby Detector Current (per zone) 4mA maximum
Maximum Detector Count (per zone) 30 detectors
Initiating Cabling Type 18AWG Twisted Shielded pair (14 - 18 AWG)
Detector Base Impedance 430 ohms
Fault Relay rating 2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating 2A & 30VAC, resistive

 


Connection Diagram

Conventional 2 Zone Fire Alarm Panel

 



Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

Conpany Profile
Conventional 2 Zone Fire Alarm PanelConventional 2 Zone Fire Alarm Panel


Assembly Line
Conventional 2 Zone Fire Alarm Panel