Industrial photoelectric smoke fire detector ( hereinafter referred to as detector ) is suitable for fire alarm in industrial sites such as substations, communication base stations, wind power generation, Photovoltaic energy storage,subway stations, motor houses and power distribution cabinets. The detector is suitable for occasions where electromagnetic interference is serious and ordinary detectors cannot be competent. The detector has the characteristics of high sensitivity, stability and reliability, low power consumption, beautiful and durable, and easy to use. After the alarm, a set of normally open ( or normally closed ) passive relay contacts are output, which can be easily used with various fire and security alarm systems.
Product Name | smoke detector with relay output | Rated operational voltage | AC90v-270V |
Sound pressure level | ≥80db | Static current | ≤2mA |
Alarm current | ≤85mA | Work temperature | -10°C~+50°C |
Output | Sound&light alarm, 6A @ 250VAC | Humidity | ≤95%. |
Functions
Work : Under normal circumstances, the indicator of the detector will flash about every 5 seconds. When the smoke concentration reaches or exceeds the alarm value, the red LED light of the detector remains bright, makes a sound, and starts the relay output.
When the smoke concentration in the environment returns to normal state, the detector automatically returns to normal state ( Alarm can automatically restore the state ).
Self-test : Press the self-test button, the detector sends an acousto-optic alarm.
The mounting hole size of the detector base is 52mm - 62mm. During installation,
two installation holes with a diameter of 5 mm were punched at a suitable position on the ceiling. As shown below , the detector base was fixed on the ceiling with a plug and screw.
Smoke detectors are not suitable for use in :
A. Places where smoke is normally held ;
B. where there are large dust, water mist, steam, oil mist pollution and corrosive gas ;
C. ventilation speed is greater than 5m / s.