Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System

Product Details
Customization: Available
Type: Fire Alarm Host
Function: Networked
Still deciding? Get samples of US$ 310/Piece
Request Sample
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System
  • Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System
  • Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System
  • Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System
  • Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System
Find Similar Products

Basic Info.

Model NO.
CA100
Certification
CE
Alarm Volume (within 1m)
≥80dB
Transport Package
Carton
Specification
320mm* 240mm*80mm
Trademark
XHA
Origin
China
HS Code
8531100000
Production Capacity
50000pieces/Year

Product Description

Addressable Fire Detection And Fire Alarm Management System
 Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System




Introduction
 
An addressable fire alarm system is a type of advanced fire detection and notification system used in commercial, industrial, and institutional buildings. Unlike traditional zone-based systems, addressable systems utilize individually addressable devices that can communicate their precise location and status back to a central control panel.
 
The key components of an addressable fire alarm system include:
 
Addressable Devices:
Smoke detectors, heat detectors, manual pull stations, and other fire detection devices are equipped with unique addresses or identifiers.Each device can report its status (normal, alarm, trouble) to the central control panel.


Addressable Fire Alarm Control Panel:
The central control panel is the brain of the system, responsible for monitoring all connected addressable devices.
It can quickly identify the specific device that has triggered an alarm or reported a trouble condition.
The control panel can initiate appropriate emergency responses, such as activating notification appliances and notifying emergency services.


Communication Network:
Addressable systems use a dedicated communication loop or network to connect the control panel with the addressable devices.
This communication network allows the panel to poll and receive status updates from each device.


Zoning and Mapping:
The control panel can associate addressable devices with specific zones or floor plans.
This provides clear visual indication of alarm locations on the control panel's display or a graphical user interface.


The key advantage of an addressable fire alarm system is its ability to pinpoint the exact location of an alarm or trouble condition, enabling a more efficient and targeted emergency response. Addressable systems also offer enhanced flexibility, scalability, and diagnostics compared to traditional zone-based systems.
 
These systems are designed and installed by qualified fire alarm professionals to meet applicable fire codes, standards, and local authority requirements. They can also integrate with other building systems, such as HVAC and access control, for a coordinated emergency management approach.

Parameters
 
Product Name Addressable Fire Alarm Control Panel Capacity 254points
Capacity Maximum 1 loop Main power supply AC220V± 15%, 2.5A, 50HZ. 
Battery power  DC 24V (1 sealed batteries: 1*12V*2.3Ah) Loop Bus wired Non-polarity 2 wired.
LCD Small size, easy Installation
 
 Operating Environment Temperature -10°C~+50°C
 Humidity ≤95%.

 Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System
 




Product Range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector



Service

1. OEM &ODM service.
2. Provide special technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

Conpany Profile
Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management SystemNon Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System


Assembly Line
Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System

Burn-in Room
Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System

Quality Management System
Non Polarity 2 Wired Addressable Fire Detection System, Fire Alarm Management System

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier