Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System

  • Audited Supplier
  • 8 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Compliance with European Standards: Designed according to EN54-2, EN54-4, and EN12094-1 standards.
  • Four Detection Zones: Supports 4 zones with a capacity of up to 30 detectors per zone.
  • Adjustable Alarm Delay: Features a delay of up to 75 seconds for extinguishing signal action.
  • High Volume Alarm: Alarm volume is at least 80dB within a 1-meter range.
  • Flexible Networking: Supports RS485 or RS232 networking modes for system integration.
  • Comprehensive Warranty: Includes a 1-year warranty covering mechanical defects.
  • Fast Lead Time: Standard production lead time is 15 working days.
  • OEM and ODM Services: Offers customized manufacturing and technical support services.

Product Images of Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System

Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System pictures & photos
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System pictures & photos
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System pictures & photos
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System pictures & photos
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System pictures & photos
Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
  • Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
  • Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
    Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
  • Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
    Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
  • Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
    Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
  • Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
    Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
  • Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System
    Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System

Find Similar Products

Product Description

Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System



Introduction

 
The automatic extinguisher control panel is designed in accordance with European
standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and
Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for
gas extinguishing systems - Part 1: Requirements and test methods for electrical
automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing
system and has four detection zones, any or all of which are capable of contributing
to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply
designed in accordance with the requirements of EN54-4.
In addition to the requirements of EN54-2 the control panel has the following
facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes.
EN54-2 Section 10 option with requirements
Delay of the actioning of fire alarm devices (sounders) so that an alarm may be
verified before a premises is evacuated. EN54-2 Section 7.11 option with
requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises
upon the detection of a fire condition or the operation of a manual call point.
EN54-2 Section 7.8 option with requirements
In addition to the requirements of EN54-2, all control panels have voltage free relay
contacts for fire and local fire which operate upon a fire condition. These are to be
used for local control and signaling.
In addition to the requirements of EN12094-1 the control panel has the following
facilities:
Delay of extinguishing signal of up to 75 seconds. EN12094-1 Section 4.17 option
with requirements.
Signal representing the flow of extinguishing agent to indicate the released
condition. EN12094-1 Section 4.18 option with requirements.
Monitoring of the status of components by way of a low pressure switch input.
EN12094-1 Section 4.19 option with requirements. Instruction Manual 5
Emergency hold device to enable the extinguishant delay time to be extended.
EN12094-1 Section 4.20 option with requirements.
Control of flooding time to deactivate the releasing output after a set period of time.
EN12094-1 Section 4.21 option with requirements.
Manual only mode to disable the release of extinguishant via automatic detection
devices. EN12094-1 Section 4.23 option with requirements.
Triggering of equipment outside the system by way of first and second stage
contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements
Activation of alarm devices with different signals to indicate pre-discharge and
released warnings using different sounds. EN12094-1 Section 4.30 option with
requirements.
 

Specification


Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System


Product Range


Smart Home Standalone smoke detectors and combustible/CO gas detector
4 wire smoke detectors with relay output.
2 wire smoke and heat detectors for switch fire sensor
Explosion-proof product for fire alarm system
Conventional Fire Alarm System
Addressable fire alarm system
Extinguishing control system
Wireless alarm system
Electrical fire monitor system
Fire door monitor system
Fire extinguishing Water cannon System
Industry 4 in 1 Gas detector/ Single gas detector(CO/CO2 etc)




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



Gas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression SystemGas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression SystemGas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression SystemGas Fire Extinguishant Control Panel for Fire Alarm Fire Suppression System

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR232771". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.

About Our Factory & Business Background

Address
Tianxin Garden Phase 3, Fuyong Town, Baoan District, Shenzhen City, Guangdong Province, China
Terms of Payment
LC, T/T, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
shenzhen

Our Production Capability & Technical Expertise

Main Products
Fire Alarm Control System, Relay Output Smoke Detector, Gas Detector, Stand Alone Smoke Detector, Electrical Fire Alarm System, Fire Door Control System, Gas Fire Extinguishing Control System, Wireless Fire Alarm System, Household Security System, Fire Alarm Control Panel

Our Industry Experience & Global Business Record

Export Year
2019-09-05
Main Markets
Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe

FAQ

What standards does this control panel comply with?
It is designed in accordance with European standards EN54-2, EN54-4, and EN12094-1.
How many detection zones does the system support?
The system supports 4 zones, with each zone capable of handling up to 30 detectors.
What is the maximum delay time for the extinguishing signal?
The control panel allows for a delay of the extinguishing signal of up to 75 seconds.
What is the alarm volume level?
The alarm volume is at least 80dB within a distance of 1 meter.
What networking modes are available?
The system supports RS485 or RS232 networking modes.
Is OEM or ODM service available?
Yes, we provide both OEM and ODM services along with technical support.
What is the warranty period?
We provide a 1-year warranty for the product.
What is the typical lead time for orders?
The normal lead time is 15 working days.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now