Basic Info.

Model NO.
XHA8015
Certification
CE
Application
Indoor, Outdoor
Working Principle
/
Transmission Mode
/
Alarm Volume (within 1m)
≥80dB
Receive Frequency
/
Product Type
2 Wire Smoke Alarm
Maximum Alarm Current
≤30mA @ 24 VDC
Standby Current
≤60µa @ 24 VDC
Working Voltage
9 to 28VDC
Adjustable Sensitivity
1.06±.26%FT
Transport Package
Carton
Specification
D103mm, H55mm
Trademark
XHA
Origin
China
HS Code
8531100000
Production Capacity
50000pieces/Year

Product Description

2 Wire Conventonal Smoke Detector For Fire Security Alarm System
Conventional Smoke Detector

Introduction

The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel.compatible with all brand conventional fire alarm system.


Parameters

 

Product Name  Smoke Detector Rated operational voltage 9 to 28VDC Volts Non-polarized
Adjustable Sensitivity 1.06±.26%FT Static current ≤60µA @ 24 VDC
Alarm current 30mA @ 24 VDC Work temperature -10°C~+50°C
Certification CE Humidity ≤95%.
Size  103*103*55mm Weight 105 g

 

 

Feature

 

Conventional Smoke Detector, Operates by Advanced MCU Expert Algorithm Software.

SMD circuit board design-satisfactory quality and reliability guaranteed

They work perfectly with all conventional intelligent fire control panels
Key Specifications/Special Features
Advanced MCU Expert Algorithm Software.
Durable sensor head, no need for replacement

Easy installation and maintenance

 

 

Installation

 


INSTALLATION
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

Remove power from initiating-device circuits before installingdetectors.
1. Wire the sensor base per the wiring diagram, Figure 1.
2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
3. After all sensors have been installed, apply power to the control unit.
4. Test the sensor(s) as described in the TESTING section of this manual.
5. Notify the proper authorities that the system is in operation.

      Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.
Conventional Smoke Detector

Conventional Smoke Detector

Product range

Conventional Fire Alarm System
Addressable fire alarm system
Gas Extinguishing control system
Beam Detector
4 wire smoke detectors with relay output.
2 wire Conventional smoke and heat detectors
Explosion-proof flame detector for fire alarm system
Standalone smoke detectors and combustable gas detector

 


Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



Conpany Profile
Conventional Smoke DetectorConventional Smoke Detector


Assembly Line
Conventional Smoke Detector

Burn-in Room
Conventional Smoke Detector

Quality Management System
Conventional Smoke Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier