• Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System
  • Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System
  • Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System
  • Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System
  • Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System

Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System

Type: Gas Fire Extinguishant Control System
Function: Fire Alarm, Gas Extinguisher
Usage: Fire Alarm
Certification: CE, CCC
Alarm Volume (within 1m): ≥80dB
Networking Mode: RS485 or RS232
Samples:
US$ 155/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (9)

Basic Info.

Receive Frequency
Wired
Wiring Mode
Sub-Line System
Mains Supply
90 to 270VAC, 50Hz/60Hz
Number of System Zones
4 Zone
Each Zone Capacity
Max 30 Detectors
Transport Package
Carton
Specification
383mm*295mm*87mm
Origin
China
HS Code
8531100000
Production Capacity
1000/Month

Product Description

Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System



Introduction

 
The automatic extinguisher control panel is designed in accordance with European
standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and
Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for
gas extinguishing systems - Part 1: Requirements and test methods for electrical
automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing
system and has four detection zones, any or all of which are capable of contributing
to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply
designed in accordance with the requirements of EN54-4.
In addition to the requirements of EN54-2 the control panel has the following
facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes.
EN54-2 Section 10 option with requirements
Delay of the actioning of fire alarm devices (sounders) so that an alarm may be
verified before a premises is evacuated. EN54-2 Section 7.11 option with
requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises
upon the detection of a fire condition or the operation of a manual call point.
EN54-2 Section 7.8 option with requirements
In addition to the requirements of EN54-2, all control panels have voltage free relay
contacts for fire and local fire which operate upon a fire condition. These are to be
used for local control and signaling.
In addition to the requirements of EN12094-1 the control panel has the following
facilities:
Delay of extinguishing signal of up to 75 seconds. EN12094-1 Section 4.17 option
with requirements.
Signal representing the flow of extinguishing agent to indicate the released
condition. EN12094-1 Section 4.18 option with requirements.
Monitoring of the status of components by way of a low pressure switch input.
EN12094-1 Section 4.19 option with requirements. Instruction Manual 5
Emergency hold device to enable the extinguishant delay time to be extended.
EN12094-1 Section 4.20 option with requirements.
Control of flooding time to deactivate the releasing output after a set period of time.
EN12094-1 Section 4.21 option with requirements.
Manual only mode to disable the release of extinguishant via automatic detection
devices. EN12094-1 Section 4.23 option with requirements.
Triggering of equipment outside the system by way of first and second stage
contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements
Activation of alarm devices with different signals to indicate pre-discharge and
released warnings using different sounds. EN12094-1 Section 4.30 option with
requirements.
 

Specification


Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System


Product Range


Smart Home Standalone smoke detectors and combustible/CO gas detector
4 wire smoke detectors with relay output.
2 wire smoke and heat detectors for switch fire sensor
Explosion-proof product for fire alarm system
Conventional Fire Alarm System
Addressable fire alarm system
Extinguishing control system
Wireless alarm system
Electrical fire monitor system
Fire door monitor system
Fire extinguishing Water cannon System
Industry 4 in 1 Gas detector/ Single gas detector(CO/CO2 etc)




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



Gas Extinguishing Controller Fire Alarm Control Panel for Fire Safety SystemGas Extinguishing Controller Fire Alarm Control Panel for Fire Safety SystemGas Extinguishing Controller Fire Alarm Control Panel for Fire Safety SystemGas Extinguishing Controller Fire Alarm Control Panel for Fire Safety System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now