Addressable Input and Output Module for Fire Alarm System

Type: Fire Alarm Linkage Module
Signal Transmission: Wired
Certification: ISO, CCC
Application: Fire Alarm
Working Principle: Electro-Optical Type
Transmission Mode: Cable
Samples:
US$ 9.2/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Guangdong, China
to see all verified strength labels (9)

Basic Info.

Model NO.
CA9008
Product
Control Module
Transport Package
Carton
Specification
85mm*86mm
Trademark
XHA
Origin
China
Production Capacity
10000/Month

Product Description

Addressable Input and Output Module for Fire Alarm System

Fire Alarm Linkage Module

Introduction


The CA9008 fire alarm linkage module is used for bus system control interface, which can control the fire linkage equipment on site (such as alarm bell, smoke exhaust valve, air supply valve, fire shutter door, fire pump, fan, etc.). The fire linkage action signal can be fed back to the fire alarm controller. 

Parameters

 
Product Name Addressable Fire Alarm Linkage Module Loop Bus wired Non-polarity 2 wired.
Power Votage DC 24V Bus Work Voltage DC17V~33V
Work current Bus Current:
Monitor current≤350uA;
Activated current≤2mA
Power Current:
Monitor current≤2mA;
Activated current≤16mA
Operating Environment Temperature:-10°C~+50°C
Humidity :≤95%.
LED Indicator Monitor Status:
red input Led flash slowly, output Led no light.
Input Activated Status:
red input LED alway light on.
Output Activated Status:
red output LED alway light on.

 
Output Normally Open,Contact Output,
Contact capacity: DC24V/2A
Dimensions 85mm×86mm Product standard  GB16806-2006


Product Range

Addressable fire alarm system
Wireless alarm system
Electrical fire monitor system
Extinguishing control system
Fire door monitor system
Standalone smoke detectors and combustible gas detector
4-wire smoke detectors with relay output.


Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



Addressable Input and Output Module for Fire Alarm SystemAddressable Input and Output Module for Fire Alarm SystemAddressable Input and Output Module for Fire Alarm SystemAddressable Input and Output Module for Fire Alarm SystemAddressable Input and Output Module for Fire Alarm System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now