8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System

Product Details
Customization: Available
Type: Fire Alarm Host
Function: Networked, Non-Networked
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (10)
  • 8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System
  • 8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System
  • 8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System
  • 8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System
  • 8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System
Find Similar Products

Basic Info.

Model NO.
XHA1008
Certification
CE
Alarm Volume (within 1m)
≥80dB
Networking Mode
Wired
Connected
Wired Conventional 8 Zone Smoke Alarm Panel
Capacity
Max 30 Conventional Detectors in One Zone
Power Supply
90-270VAC
Back up Battery
1*12V Sealed Lead Acid
Transport Package
Carton
Specification
370mm*440mm*100mm
Trademark
XHA
Origin
China
HS Code
8531100000
Production Capacity
50000pieces/Year

Packaging & Delivery

Package Size
37.00cm * 44.00cm * 10.00cm
Package Gross Weight
4.500kg

Product Description

8 Zone Conventional Fire Alarm Controller For Fire Safety Alarm System

8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System

 

 



Introduction

 

The information provided in this manual covers the Master and Slave fire alarm control panel. The panel range is designed to
meet the requirements of EN54 Parts 2 & 4.
A comprehensive range of auxiliary devices is available to operate with the fire control panels including optical, ionization,
photoelectric, photoelectric-thermal and heat detectors.
Each of the system components has been specifically designed to operate as part of the system. This provides assurance
that the control panel, smoke detectors, interface devices and the ancillary components are all fully compatible with one
another and that the full range of system functionality is supported by each device.
The fire alarm control panels (8 Zones) provide all of the sophisticated features required of a leading edge conventional fire
alarm system along with the simple operation and efficient installation methods demanded by both installers and building
users


Product Features

 
8 conventional input zones.
Housed in a 370mm W x 440mm H x 100mm D metal enclosure.
Each zone can be connected with 30 conventional fire detectors. Each panel has external devices control output points, Through the points, the panel can control such external devices as bell, siren, flame detector, beam detector etc.
Dedicated alarm and trouble relays.
Enclosure supports 1 12V, 4.5Ah backup batteries.
The panel can be used independently or connect by RS485.
1 RS485 can be able to connect the other panel.
 

Specification

 

 

Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.90 Amps @ 26VDC
Initiating Device Circuits Zones Alarm Zone 2/4/8/16
Normal Initiating Operating Voltage 22VDC, Maximum 26VDC, regulated
Normal Monitor Current <50mA
Alarm Current <150 mA
Short Circuit Initiating Current (per zone) 35mA Maximum
Maximum Initiating Resistance (per zone) 10 ohms
Initiating End-of-Line Resistor 4K7 ohms, 1/2W 5%
Standby Detector Current (per zone) 4mA maximum
Maximum Detector Count (per zone) 30 detectors
Initiating Cabling Type 18AWG Twisted Shielded pair (14 - 18 AWG)
Detector Base Impedance 430 ohms
Fault Relay rating 2A & 30VAC, resistive
Alarm( Auxiliary ) Relay rating 2A & 30VAC, resistive

 


Connection Diagram

8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System

Service


1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.

Conpany Profile
8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System


Assembly Line
8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System

Burn-in Room
8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System

Quality Management System
8 Zone Conventional Fire Alarm Controller Red for Fire Safety Alarm System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier