Product Highlights

  • EN54 & EN12094 Certified: Complies with EN54-2, EN54-4, and EN12094-1 European standards for safety and reliability.
  • 4-Zone Detection Capacity: Supports up to 4 detection zones with a capacity of max 30 detectors per zone.
  • Flexible Networking Options: Offers RS485 or RS232 networking modes for versatile system integration.
  • Adjustable Delay Control: Features up to 75-second delay for extinguishing signal and emergency hold device.
  • OEM & ODM Services: Provides customized manufacturing solutions and technical support for specific needs.
  • Fast Lead Time: Normal lead time is 15 working days, ensuring quick delivery for orders.
  • Wide Mains Supply Range: Operates on 90 to 270VAC, 50Hz/60Hz, compatible with global power standards.

Product Images of Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems

Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems pictures & photos
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems pictures & photos
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems pictures & photos
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems pictures & photos
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems pictures & photos
Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
  • Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
  • Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
    Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
  • Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
    Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
  • Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
    Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
  • Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
    Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
  • Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems
    Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems

Find Similar Products

Product Description

Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems



Introduction

 
The automatic extinguisher control panel is designed in accordance with European
standards EN54-2 and EN54-4 Fire Detection and Fire Alarm systems - Control and
Indicating Equipment and EN12094-1 Fixed firefighting systems - Components for
gas extinguishing systems - Part 1: Requirements and test methods for electrical
automatic control and delay devices.
The control equipment is a combined fire alarm control panel and extinguishing
system and has four detection zones, any or all of which are capable of contributing
to the extinguishant release decision.
Control panels have an integral, mains powered battery charger and power supply
designed in accordance with the requirements of EN54-4.
In addition to the requirements of EN54-2 the control panel has the following
facilities:
Test condition to allow the automatic resetting of zones in alarm for testing purposes.
EN54-2 Section 10 option with requirements
Delay of the actioning of fire alarm devices (sounders) so that an alarm may be
verified before a premises is evacuated. EN54-2 Section 7.11 option with
requirements.
Fire alarm devices to enable an audible warning to be sounded throughout premises
upon the detection of a fire condition or the operation of a manual call point.
EN54-2 Section 7.8 option with requirements
In addition to the requirements of EN54-2, all control panels have voltage free relay
contacts for fire and local fire which operate upon a fire condition. These are to be
used for local control and signaling.
In addition to the requirements of EN12094-1 the control panel has the following
facilities:
Delay of extinguishing signal of up to 75 seconds. EN12094-1 Section 4.17 option
with requirements.
Signal representing the flow of extinguishing agent to indicate the released
condition. EN12094-1 Section 4.18 option with requirements.
Monitoring of the status of components by way of a low pressure switch input.
EN12094-1 Section 4.19 option with requirements. Instruction Manual 5
Emergency hold device to enable the extinguishant delay time to be extended.
EN12094-1 Section 4.20 option with requirements.
Control of flooding time to deactivate the releasing output after a set period of time.
EN12094-1 Section 4.21 option with requirements.
Manual only mode to disable the release of extinguishant via automatic detection
devices. EN12094-1 Section 4.23 option with requirements.
Triggering of equipment outside the system by way of first and second stage
contacts, extract fan output etc. EN12094-1 Section 4.26 option with requirements
Activation of alarm devices with different signals to indicate pre-discharge and
released warnings using different sounds. EN12094-1 Section 4.30 option with
requirements.
 

Specification


Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems


Product Range


Smart Home Standalone smoke detectors and combustible/CO gas detector
4 wire smoke detectors with relay output.
2 wire smoke and heat detectors for switch fire sensor
Explosion-proof product for fire alarm system
Conventional Fire Alarm System
Addressable fire alarm system
Extinguishing control system
Wireless alarm system
Electrical fire monitor system
Fire door monitor system
Fire extinguishing Water cannon System
Industry 4 in 1 Gas detector/ Single gas detector(CO/CO2 etc)




Service

1. OEM &ODM service.
2. Provide technical support and after-sale service.
3. 1 year warranty.
4. Normally 15 working days lead time.

5. Welcome sample order.



Gas Fire Extinguisher Controller for Fire Alarm & Fire Fighting SystemsGas Fire Extinguisher Controller for Fire Alarm & Fire Fighting SystemsGas Fire Extinguisher Controller for Fire Alarm & Fire Fighting SystemsGas Fire Extinguisher Controller for Fire Alarm & Fire Fighting Systems

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR232771". Items marked "verified" are certified.

Watch Video
Watch Video
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.
Shenzhen Xinhean Technology Co., Ltd.

About Our Factory & Business Background

Address
Tianxin Garden Phase 3, Fuyong Town, Baoan District, Shenzhen City, Guangdong Province, China
Terms of Payment
LC, T/T, PayPal, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB
Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
Nearest Port
shenzhen

Our Production Capability & Technical Expertise

Main Products
Fire Alarm Control System, Relay Output Smoke Detector, Gas Detector, Stand Alone Smoke Detector, Electrical Fire Alarm System, Fire Door Control System, Gas Fire Extinguishing Control System, Wireless Fire Alarm System, Household Security System, Fire Alarm Control Panel

Our Industry Experience & Global Business Record

Export Year
2019-09-05
Main Markets
Eastern Europe, Southeast Asia, Africa, Mid East, Eastern Asia, Western Europe

FAQ

What certifications does the controller have?
The controller is certified with CE and CCC, and designed in accordance with European standards EN54-2, EN54-4, and EN12094-1.
How many detection zones are supported?
The system supports 4 zones, with each zone capable of connecting up to 30 detectors.
What is the lead time for orders?
The normal lead time is 15 working days, applicable for both peak and off-peak seasons.
Does the product offer warranty and support?
Yes, we provide a 1-year warranty along with technical support and after-sale service.
What networking modes are available?
The controller supports RS485 or RS232 networking modes for system connectivity.
Can I place a sample order?
Yes, sample orders are welcome for quality verification before bulk purchase.
What payment methods are accepted?
We accept LC, T/T, PayPal, Western Union, and Money Gram for payments.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now